30 Faults in BQ24103ARHLR You Should Know to Prevent Charging Issues
30 Faults in BQ24103ARHLR You Should Know to Prevent Charging Issues
The BQ24103ARHLR is a highly integrated charger IC that supports charging lithium-ion batteries. However, like any complex electronic component, it can experience various faults that could cause charging issues. Below is a breakdown of common faults, the causes behind them, and step-by-step solutions to help you troubleshoot effectively.
1. No Output Voltage Cause: The charger might not be delivering the expected output voltage. Solution: Check if the input voltage to the charger is within the specified range (typically 4.5V to 5.5V). Inspect the PCB for any broken traces or poor solder joints. Ensure the feedback loop (FB pin) is properly connected. 2. Charger Not Charging the Battery Cause: The charger isn't detecting the battery or isn’t charging it properly. Solution: Verify that the battery is correctly connected to the BAT+ and BAT- pins. Ensure the battery's voltage is within the charging range. Check the status of the CHG (charge status) pin to confirm charging is active. 3. Overheating of the Charger IC Cause: The IC could overheat due to excessive current draw or improper thermal management. Solution: Ensure proper heat dissipation by adding a heatsink or improving airflow around the IC. Check if the current settings (via the ISET pin) are correctly configured for the battery’s rated charging current. 4. Charging Current Too Low Cause: Charging current is lower than expected, resulting in slow charging. Solution: Verify that the ISET pin is set to the correct value for the